Power Line Filters with Line Legs

Power Line Filters with Line Legs

 Power Line Filters with Line Legs at load side 8030

Power and signal line filters designed for high performance shielded cabinets, shielded rooms and anechoic chambers. Shielding performance: 100dB @ 14KHz-40GHz (MIL-STD-285)

 

The 8030 series power line filters with line legs at load side is capable of providing a radiated transmission loss of 100 dB at 14 kHz up to 40 GHz. The leakage current is in milliampere level and the voltage drop is less than 1 V.

Applications:
  • Shielded rooms
  • Shielded chambers
  • Anechoic chambers
  • Military applications
  • Medical applications
Advantages:
  • Applicable in very low frequency (VLF) applications
  • Can be delivered EMP-proof
  • Suitable for use under extreme conditions (military applications)
  • Wear resistant
  • Insensitive to corrosion
8030 series Power line filter with line legs at load side with open lid
8030 series Power line filter with line legs at load side with closed lid

Technical data

Rated voltage VR for two-line filters250 VAC / 500 VDCline-line or line-case
Rated voltage VR for four-line filtersup to 440 VAC
up to 220 VAC
line-line
line-case
Rated Frequency fRDC -60 Hz 
Rated Current IRSee characteristicsreferred to + 40 °C ambient temperature
Number of lines2/4 
Test voltage1200 VDC / 2 sline-line or line-case
Voltage drop/phase ΔV< 1 %of VR at 50 Hz and IR
Leakage current I LeakageSee characteristicsat 380 V / 220 V and 50 Hz
Reactive Current I ReactiveSee characteristicsat 380 V / 220 V and 50 Hz
Discharge Time to Below 34 V30 S 
Climatic category25/070/21

Dimensional Diagrams

Diagram 1
Diagram 3

Power line filters with line legs at load side diagram 5Diagram 5

Diagram 2

Power line filters with line legs at load side diagram 4

Diagram 4

                                                                                                                           Available Dimensions
 Part numberABCDEFGinstallation instructionsOutline drawingIR (A)I Leakage (A)*Terminal connectionTransmission loss
             inout  
 8030-2-62251007045M16 conduit screw12×6 0.002Line legs Line legs 

 

 

 

 

 

 

 

 

 

 

100dB, 14k-40GHz

 8030-2-1662012080535605045M33 conduit screw22×160.002M6 ScrewLine legs
 8030-2-3262012080535605045M33 conduit screw22×320.02M6 ScrewLine legs
 8030-2-63800160120715805045M33 conduit screw22×630.15M6 ScrewLine legs
 8030-2-1008802001507901205033M60 conduit screw32×1000.15M12 ScrewLine legs
 8030-2-2008802001507901205033M60 conduit screw32×2000.15M12 ScrewLine legs
 8030-2-2508802001507901205033M60 conduit screw32×2500.15M12 ScrewLine legs
 8030-4-16720240806351405045M33 conduit screw44×160.005M6 ScrewLine legs
 8030-4-32720240806351405045M33 conduit screw44×320.005M6 ScrewLine legs
 8030-4-639003201208151605045M33 conduit screw44×630.005M6 ScrewLine legs
 8030-4-1009003201507901805033M60 conduit screw54×1000.05M12 ScrewLine legs
 8030-4-2009003201507901805033M60 conduit screw54×2000.05M12 ScrewLine legs
 8030-4-2509003201507901805033M60 conduit screw54×2500.05M12 ScrewLine legs

* If voltage between neutral and earth is 0V Actual size may differ from the above. Sizes may vary to the size chart. Please contact us for the correct size

Get a Quotation

Fill in the form below.