The 8080 HEMP/NEMP powerline filters are designed to withstand the PCI test known as E1, E2 and E3 while largely exceeding the shielding effectiveness as stated in MIL-STD-188-125.
Our R&D specialist has designed the filters so they meet the highest shielding demands with an insertion loss of 100 dB @ 9 kHz and 120 dB @ 20 kHz.
All filters are tested in our in-house E1/E2 testing facility to ascertain they meet the highest standards and quality.
As the only powerline filter supplier in the world that has an E1 and E2 pulse tester in-house, Holland Shielding has the capacity to test, certify and supply the filters within a very short turnaround time.
Features:
8080 – Shielding performance
🟥 8080 Series |
⬛ MIL-STD-188-125 |
Please note : These values are measured under laboratory conditions. Results may vary in other situations; Please read our Guarantee.
Test pulse (5 kA)
Residual pulse (800 mA)
Product range:
Type | L (mm) | W (mm) | H (mm) | Ir(A) | I leakage | Lines | Voltage | 100dB@ | 120dB@ |
8080-2-16 | 720 | 90 | 130 | 16 | 4.3 A | 2 | 230 V / 440 VAC | 9 kHz | 14 kHz |
8080-2-32 | 720 | 90 | 130 | 32 | 4.3 A | 2 | 230 V / 440 VAC | 9 kHz | 14 kHz |
8080-2-63 | 720 | 90 | 130 | 63 | 4.3 A | 2 | 230 V / 440 VAC | 9 kHz | 14 kHz |
8080-4-16 | 770 | 150 | 150 | 16 | 8.6 A | 4 | 230 V / 440 VAC | 14 kHz | 27 kHz |
8080-4-32 | 770 | 150 | 150 | 32 | 8.6 A | 4 | 230 V / 440 VAC | 14 kHz | 27 kHz |
8080-4-63 | 770 | 150 | 150 | 63 | 8.6 A | 4 | 230 V / 440 VAC | 14 kHz | 27 kHz |
8080-4-100 | 770 | 150 | 150 | 100 | 8.6 A | 4 | 230 V / 440 VAC | 14 kHz | 27 kHz |
8080-4-200 | 770 | 150 | 150 | 200 | 10.3 A | 4 | 230 V / 440 VAC | 14 kHz | 27 kHz |
Insertion loss and E1, E2 and E3 pulse testing facility
As the only filter producer that can perform individual pulse testing, we are able to guarantee that your filter will protect your facility and not just on paper. Our filters are tested in our in-house test facility with which we are capable to perform PCI as per E1 (20 / 500 ns 2.5 kA peak) and E2 (1.5 / 4000 µs 250 A peak) test pulses. With our testing facilities we make sure our filters comply with the highest standards, demands and that the residual currents are within limits of the applicable standards and norms.
The intense electromagnetic pulse (EMP) is generated by the phenomenon called “Compton effect” or “Compton scattering”. The nuclear explosion that generates this transient electromagnetic disturbance is also know as NEMP (Nuclear Electromagnetic Pulse) or HEMP (High Altitude Electromagnetic Pulse). The HEMP is typically defined as a combination of three consecutive pulses called early time (E1), intermediate-time (E2) and late-time (E3), as shown in the graph below.
Get a Quotation
Fill in the form below
© Copyright 2022 Japan Homeland security Corporation. All Rights Reserved.