For shielded rooms where the effective suppression of radiated emission is required. Shielding performance: 100 dB @ 14 kHz-40 GHz (MIL-STD-285)

The Compact high performance power line filters are capable of providing a radiated transmission loss of 100 dB at 14 kHz up to 40 GHz. The leaked current is in milliampere level and the voltage drop is less than 1 V.

 

The filter is made to withstand the harshest environment, and it is very economical. Because it is custom designed for your own filter, the assembly is very simple and emits very low leakage. This filter is usually in a stock and normally available. 

 

This series is offered as a two line filter (single phase and neutral) or as a four line filter (three phases and neutral). The two line filter can withstand up to 230 Volt, 1-1000 amp and 46 kW. If you are looking for a filter that can withstand more power then the four line filter is recommended. This four line filter delivers up to 400 Volt, 1-1600 amp and 138 kW. The neutral line is always attenuated and all conductors are decoupled from each other. This allows the conductors to operate independently without attenuation loss.

 

The circuit is designed as a symmetrical double- circuit with high quality rod cores providing inductance. These cores do not saturate due to their large air gap and they are insensitive to asymmetrical load.

 

Foil capacitors ensure a long operating life by their self healing feature even after voltage transients. A seamless fixing of the filter casing to the shielded room is very important to ensure trouble free operation. The filter is housed in a casing that has a base flange and provides stable mounting and excellent earthing when bolted to the shielded room via the mounting bolts.

Please note: EMP protection is available on request.

Also, check our Ultra high-performance filters.

 

Advantages:

  • Applicable in very low frequency (VLF) applications
  • Can be delivered EMP-proof
  • Suitable for use under extreme conditions (military applications)
  • Wear resistant
  • Insensitive to corrosion

Applications:

  • Shielded rooms
  • Shielded chambers
  • Anechoic chambers
  • Military applications
  • Medical applications

Mounting:

These protections are designed for mounting on the penetration panel or directly on the non-painted wall of the Faraday cage. Mounting terminals are dependent on the amount of power. Please see Connection in the Product range table.

 

Installation diagram:

The technical drawing below shows how a power line filter is mounted on the wall a your Faraday cage.

Technical data:

Rated voltage VR for two-line filters250 VAC/500 VDCline-line or line-case
Rated voltage VR for four-line filters440 VAC
250 VAC
line-line
line-case
Rated Frequency fRDC -60 Hz 
Rated Current IRSee characteristicsreferred to +40 °C ambient temperature
Number of lines2/4 
Test voltage1200 VDC / 2 sLine-line or line-case
Voltage drop/phase ΔV<1%of VR at 50 Hz and IR
Leakage current I LeakageSee characteristicsat 380 V / 220 V and 50 Hz
Reactive current I ReactiveSee characteristicsat 380 V / 220 V and 50 Hz
Discharge Time to Below 34 V30 s 
Climatic category25/070/21 
Shielding performance100 dB @14 kHz ~ 40 GHz
Insertion loss100 dB @50 kHz ~ 40 GHz

Shielding performance:

Please note : These values are measured under laboratory conditions and may vary in other situations; Please read our Guarantee.

Single phase and neutral filter types:

230 Volt, 1-1000 amp and 230 kVA

Outline drawing 1
Outline drawing 2
TypeABCDEFGInstallation instructionsOutline drawingIR (A)Leakage (A)*Reactive (A)Terminal connectionShielding Effectiveness (dB)
InOut
8020-2-1618820512075045011080M24 conduit screw12×160.021.7M6 ScrewM6 Screw

 

 

 

 

 

 

 

 

 

100 dB,
14 kHz
~
40 GHz

8020-2-3218820512075045011080M24 conduit screw12×320.021.7M6 ScrewM6 Screw
8020-2-6318820514092062011080M33 conduit screw12×630.021.7M6 ScrewM6 Screw
8020-2-10022824515596045020580M60 conduit screw12×1000.157.0M12 ScrewM12 Screw
8020-2-20022824515596045020580M60 conduit screw12×2000.157.0M12 ScrewM12 Screw
8020-2-25022824515596045020580M60 conduit screw12×2500.157.0M12 ScrewM12 Screw
8020-2-4003203402051360850170120 22×4000.307.0Bus barBus bar
8020-2-6303703902251300800170105 22×6300.457.0Bus barBus bar
8020-2-8004855052551450900185115 22×8000.587.0Bus barBus bar
8020-2-10005105302551450900185115 22×10000.587.0Bus barBus bar
* If voltage between neutral and earth is 0V
Actual size may differ from the above. Please contact us for the correct size

 

Three phases and neutral filter types:

400 Volt, 1-1600 amp and 1100 kVA

Outline drawing 3
Outline drawing 4
TypeABCDEFGInstallation instructionsOutline drawingIR (A)Leakage (A)*Reactive (A)Terminal connectionShielding Effectiveness (dB)
InOut
8020-4-1628830512075045011080M33 conduit screw34×160.0051.7M6 ScrewM6 Screw100 dB,
14 kHz
~
40 GHz
8020-4-3228830512075045011080M33 conduit screw34×320.0051.7M6 ScrewM6 Screw
8020-4-6334836514092062011080M33 conduit screw34×630.0051.7M6 ScrewM6 Screw
8020-4-10034836515596045020580M60 conduit screw34×1000.057.0M12 ScrewM12 Screw
8020-4-20034836515596045020580M60 conduit screw34×2000.057.0M12 ScrewM12 Screw
8020-4-25038840515596045020580M60 conduit screw34×2500.057.0M12 ScrewM12 Screw
8020-4-4005365562051360850170120 44×4000.087.0Bus barBus bar
8020-4-6306706902251300800170105 44×6300.17.0Bus barBus bar
8020-4-8009009202551450900185115 44×8000.127.0Bus barBus bar
8020-4-10009459652551450900185115 44×10000.127.0Bus barBus bar
8020-4-120091093027517901150270125 44×12000.187.0Bus barBus bar
8020-4-140091093027517901200280110 44×14000.187.0Bus barBus bar
8020-4-160088090028519301200280110 44×16000.247.0Bus barBus bar
* If voltage between neutral and earth is 0V
Actual size may differ from the above. Please contact us for the correct size